     Input power | 
     DC24V±10% (0.5Amax) | 
   
   
     | Operating temperature | 
     0 to 50℃ | 
   
   
     | Communication method | 
     Host device | 
     RS-232C communication: Ladder editing and parameter settings using a PC. | 
   
   
     | Indicator | 
     RS-422: touch panel, etc., MEMOBUS protocol | 
   
   
     | Servo driver | 
     RS-485:Communicate with Cuty Axis,Si servo. | 
     - | 
   
   
     | Control input | 
     Number of Channels | 
     32 points: Photo-coupler input 
       * can be expanded up to a maximum of 64 points | 
   
   
  
   
     | Control output | 
     Number of Channels | 
     32 points: Photo-coupler output 
* can be expanded up to a maximum of 64 points | 
   
   
     | Manual pulser | 
     Counter input | 
     Power supply: 5V (internal current consumption: 0.2Amax) | 
   
   
     | Dedicated input and output | 
     Input: 7 points, Output: 1 point 
 (The same as the control input and output for specifications) | 
   
   
     | Servo control
       
      | Counter input
      | Servo ready, alarm, in-position | 
   
   
     | Counter output | 
     Servo on, origin start, alarm reset | 
   
   
     | Position feedback input | 
     Communication | 
     Line receiver 
       90 ° phase difference 2-phase pulse train | 
   
   
     | Command pulse output | 
     Method | 
     Line driver, 90 ° phase difference 2-phase pulse train | 
   
   
     | Frequency | 
     1pps~2Mpps (Multiplied by 4) | 
   
   
     
       | 
     Maximum number of control axis | 
     4-axis | 
   
   
     | Control method | 
     Position control | 
   
   
     | Operation program | 
     G code | 
   
   
     | Automatic feed | 
     Positioning (PTP), linear interpolation (simultaneous 4-axis),  
        Circular interpolation (selection 2-axis), helical interpolation | 
   
   
     | Manual feed | 
     Manual feed (JOG), step feed, homing, manual pulser (1ch) | 
   
   
     | Command unit | 
     pulse | 
   
   
     | Maximum command position | 
     ±2147483647 | 
   
   
     | Speed command unit | 
     pulse/sec(pps) | 
   
   
     | Acceleration and deceleration function | 
     Linear acceleration and deceleration | 
   
   
   
     | Override function | 
     Rapid-traverse override: 0 to 100% (16 steps) | 
   
   
     | Cutting feed override: 0 to 150% (16 steps) | 
   
   
     | Manual feed override: 0 to 100% (16 steps) | 
   
   
   
       | 
     Program method | 
     Relay symbol system | 
   
   
     | Program memory | 
     FLASH ROM | 
   
   
     | Program capacity | 
     16000 steps | 
   
   
     | Arithmetic processing speed | 
     Basic instruction 1.2μsec / step | 
   
   
     | Constant scan | 
     10-200msec  (5msec unit) | 
   
   
     | Basic instruction | 
     24 kinds | 
   
   
     | Application command | 
     80 kinds | 
   
   
     | Input(X) | 
     1024 | 
   
   
     | Output(Y) | 
     1024 | 
   
   
     | Internal relay(M) | 
     16000 | 
   
   
     | Timer(T) | 
     1024 * low speed (1000msec), medium speed (100msec),
high-speed (10msec) | 
   
   
     | Counter(C) | 
     1024,Up counter | 
   
   
     | Data register | 
     16000 words | 
   
   
     | Battery backup | 
     The holding area is set by the user parameters. (external battery backup) |